SourcingAI

Auxiliary transformer manufacturers

I have found results from400+products and200+suppliers aboutAuxiliary transformer

Zhejiang Dahu Electric Co., Ltd.mic-icon
Satisfies 1/1 of your requirement
Jdj2-33 Single Phase Pole Mounted Oil Filled Auxiliary Instrument Voltage Transformer

Jdj2-33 Single Phase Pole Mounted Oil Filled Auxiliary Instrument Voltage Transformer

US$100.00
1 Piece(MOQ)
Factory Supply 6300-100000kVA Two-Winding Power Transformer with Oltc - 110/220kv-6.3/10.5kv for Nuclear Power Auxiliary Systems

Factory Supply 6300-100000kVA Two-Winding Power Transformer with Oltc - 110/220kv-6.3/10.5kv for Nuclear Power Auxiliary Systems

US$1,500.00-3,000.00
1 Piece(MOQ)
Sample Available
Three-Phase Pad Mounted Distribution Transformer with Pressure Relief Valve -12.47kv Hv for Factory Auxiliary Equipment

Three-Phase Pad Mounted Distribution Transformer with Pressure Relief Valve -12.47kv Hv for Factory Auxiliary Equipment

US$50.00
1 Piece(MOQ)
50/60Hz Three-Phase Pad Mounted Distribution Transformer -12.47kv Hv for Construction Machinery Auxiliary Power

50/60Hz Three-Phase Pad Mounted Distribution Transformer -12.47kv Hv for Construction Machinery Auxiliary Power

US$50.00
1 Piece(MOQ)
High Reliability Single-Phase Pad Mounted Distribution Transformer – 7.62-19.92kv Hv for Factory Auxiliary Power

High Reliability Single-Phase Pad Mounted Distribution Transformer – 7.62-19.92kv Hv for Factory Auxiliary Power

US$50.00
1 Piece(MOQ)
Low Cost Single-Phase Overhead Distribution Transformer – Amorphous Core for Industrial Auxiliary Equipment

Low Cost Single-Phase Overhead Distribution Transformer – Amorphous Core for Industrial Auxiliary Equipment

US$50.00
1 Piece(MOQ)
High-Efficiency Single-Phase Pad Mounted Distribution Transformer – 25-250kVA for Airport Auxiliary Power

High-Efficiency Single-Phase Pad Mounted Distribution Transformer – 25-250kVA for Airport Auxiliary Power

US$50.00
1 Piece(MOQ)
High-Voltage Bushing Three-Phase Pad Mounted Distribution Transformer -12.47kv Hv for Industrial Auxiliary Power

High-Voltage Bushing Three-Phase Pad Mounted Distribution Transformer -12.47kv Hv for Industrial Auxiliary Power

US$50.00
1 Piece(MOQ)
Cu-Cu Winding Single-Phase Overhead Distribution Transformer – High Efficiency for Industrial Auxiliary Equipment

Cu-Cu Winding Single-Phase Overhead Distribution Transformer – High Efficiency for Industrial Auxiliary Equipment

US$50.00
1 Piece(MOQ)
Single-Phase Overhead Distribution Transformer – CRGO Core 15-167kVA, Cu-Cu Winding 7.97kv-600V for Industrial Auxiliary

Single-Phase Overhead Distribution Transformer – CRGO Core 15-167kVA, Cu-Cu Winding 7.97kv-600V for Industrial Auxiliary

US$50.00
1 Piece(MOQ)
167kVA Single-Phase Overhead Distribution Transformer – CRGO Core, 7.97kv-600V for Industrial Auxiliary Equipment

167kVA Single-Phase Overhead Distribution Transformer – CRGO Core, 7.97kv-600V for Industrial Auxiliary Equipment

US$50.00
1 Piece(MOQ)
Single-Phase Overhead Distribution Transformer – CRGO Core 15-167kVA, 14.4kv-600V for Industrial Auxiliary Equipment

Single-Phase Overhead Distribution Transformer – CRGO Core 15-167kVA, 14.4kv-600V for Industrial Auxiliary Equipment

US$50.00
1 Piece(MOQ)
Sealed Single-Phase Pad Mounted Distribution Transformer – 7.62-19.92kv Hv for Railway Station Auxiliaries

Sealed Single-Phase Pad Mounted Distribution Transformer – 7.62-19.92kv Hv for Railway Station Auxiliaries

US$50.00
1 Piece(MOQ)
7.62kv Hv Single-Phase Pad Mounted Distribution Transformer- Lightweight for Commercial Center Auxiliaries

7.62kv Hv Single-Phase Pad Mounted Distribution Transformer- Lightweight for Commercial Center Auxiliaries

US$50.00
1 Piece(MOQ)
60Hz Single-Phase Overhead Distribution Transformer – 15-75kVA for Industrial Auxiliary Instruments

60Hz Single-Phase Overhead Distribution Transformer – 15-75kVA for Industrial Auxiliary Instruments

US$50.00
1 Piece(MOQ)

Sourcing guidance for Auxiliary Transformer

What are the key technical specifications to consider when selecting an auxiliary transformer?

When sourcing auxiliary transformers, buyers must prioritize rated capacity (kVA), voltage ratios (e.g., 11kV/415V), and insulation class (Class H or F). It is critical to verify the cooling method, typically ONAN (Oil Natural Air Natural) for outdoor units or AN (Air Natural) for dry-type indoor units. Additionally, ensure the vector group (e.g., Dyn11) matches your existing power system configuration to prevent phase displacement issues.

Which international compliance standards are mandatory for auxiliary transformers?

To ensure safety and grid compatibility, products must adhere to IEC 60076 for power transformers or IEEE C57.12.00 for North American markets. For European regions, CE marking and compliance with the Ecodesign Directive (Tier 2) for energy efficiency are essential. If the unit is intended for hazardous environments, ATEX or IECEx certification for explosion-proof integrity is required.

How can I evaluate the energy efficiency and economic feasibility of a transformer?

Focus on the No-Load Loss (Iron Loss) and Load Loss (Copper Loss) values provided in the technical data sheet. High-efficiency units using amorphous metal cores can reduce energy waste by up to 70% compared to traditional silicon steel, offering a better Total Cost of Ownership (TCO) over a 20-year lifespan despite a higher initial purchase price.

What usage scenarios dictate the choice between dry-type and oil-immersed auxiliary transformers?

Dry-type transformers are preferred for indoor installations, high-rise buildings, and underground stations due to their fire-resistant properties and low maintenance. Conversely, oil-immersed transformers are more suitable for outdoor substations and heavy industrial sites because of their superior heat dissipation and better protection against harsh environmental contaminants.

Cross-Border Procurement & Risk Management for Transformers

How can I mitigate the risks of damage during international shipping?

Transformers are heavy and sensitive equipment. Ensure the supplier uses seaworthy vacuum packaging and heavy-duty steel skids. It is mandatory to request the installation of Impact Recorders (Shockwatch) on the crate to monitor mishandling during transit. For oil-filled units, verify if they are shipped with or without oil; shipping 'dry' (filled with nitrogen) reduces weight but requires specialized onsite filling.

What are the best strategies for negotiating with industrial electrical suppliers?

Focus on Routine Test Reports and Type Test Reports as negotiation leverage. A supplier willing to provide KEMA or CESI lab certifications justifies a premium price. For bulk orders, negotiate for extended warranties (24-36 months) and the inclusion of critical spare parts (such as bushings and gaskets) in the initial contract price.

How do I ensure transaction security and quality verification from a distance?

Utilize secured payment terms and consider hiring a third-party inspection agency (like SGS or Intertek) to perform a Factory Acceptance Test (FAT) before final payment. When sourcing via Made-in-China.com, prioritize Audited Suppliers who have undergone comprehensive on-site verification of their manufacturing capabilities and financial standing.

What logistics considerations apply to shipping to specific global regions?

Check for import duties and anti-dumping regulations specific to electrical machinery in your country. Ensure the HS Code (typically 8504) is correctly declared to avoid customs delays. For inland delivery, confirm that the local port has the heavy-lift crane capacity required to handle the transformer's gross weight.

Related queries