Product Attributes:
Universal Testing Machine
B Type Insulator
Installation: Portable Precise
Display: Digital
Meter for Industry and Home Use
Theory: Electronic Meter
AC and DC
DC Voltmeter Type: Electrostatic
AC Voltmeter Type: Electrostatic
Customized: Customized
Accuracy: 0.1
Application: Electric Power
Control: Computer Control
Weight: 0-100Kg
Analogue and Digital
Certification: RoHS
Material: FRP/GRP
Connection Method: Spherical Type
Color: Yellow
Load Way: Electronic Load
Loading Method: Dynamic Load
Function: Protection
Condition: New
Max Diameter of Workpiece: <500mm
Mass Scope of Workpiece: <900kg
Maxcapacity: <1000KN
Accuracy Grade: 0.5
Oil Cylinder Position: Under
Display: Indicator
Display: Needle
Maximum Demand Meter
Standard Electric Energy Meter
Multi-Functional Energy Meter
Multi-rate Watt-hour Meters
Usage: Watt-Hour Meter
Reactive Energy Meter
Usage: Prepayment Meter
High Voltage Power Transmission
Usage: Insulation
Theory: Machine-electric Type
Theory: Induction Meter
Power Source: AC
Power Source: AC220V
DC Voltmeter Type: Magnetic
AC Voltmeter Type: Electric
AC Voltmeter Type: Electromagnetic
Customized: Non-Customized
Application: High-voltage
Control: Manual Control
Certification: CE
Certification: CCC
Certification: ISO9001
Certification: ISO

Sourcing guidance for Non Contact Voltage Detector

What are the key technical specifications to consider when selecting a Non-Contact Voltage Detector (NCVD)?

When sourcing NCVDs, prioritize the Voltage Detection Range, typically spanning from 12V to 1000V AC to cover both low-voltage controls and high-voltage industrial lines. Ensure the device features Dual Sensitivity modes (High/Low) for precise troubleshooting. Look for a CAT III 1000V or CAT IV 600V safety rating, which is the industry standard for protecting users against transient voltage spikes in fixed installations.

Which safety and compliance standards are mandatory for international trade?

Compliance is non-negotiable for electrical tools. Ensure the products carry the CE mark for the European market and UL or ETL certification for North America. The device must adhere to IEC 61010-1 safety requirements. Additionally, verify RoHS compliance to ensure the absence of hazardous substances in the plastic casing and electronic components.

What functional features enhance the product's value for professional B2B buyers?

High-quality detectors should include an Audible and Visual Alarm (LED and Buzzer) that increases in intensity as it nears the voltage source. A built-in LED flashlight is a critical value-add for technicians working in dark panels. Furthermore, an Auto Power-Off (APO) function is essential to preserve battery life, and a Low Battery Indicator ensures the tool is always ready for safe use.

How can I evaluate the durability and build quality of the detector?

Request information on the IP Rating (e.g., IP54 or IP67) to ensure resistance to dust and water splashes in rugged environments. The casing should be made of impact-resistant ABS plastic or reinforced with a rubber over-mold to survive 2-meter drop tests. For bulk orders, ask for a MTBF (Mean Time Between Failure) report to gauge long-term reliability.

Cross-Border Procurement Strategy & Risk Management

How can I mitigate the risk of receiving substandard electrical safety tools?

Always request a Pre-Shipment Inspection (PSI) conducted by a third-party agency like SGS or Intertek. Specifically, instruct them to perform a Dielectric Withstand Test and a Functionality Test on a random sample. When sourcing via Made-in-China.com, prioritize Audited Suppliers whose manufacturing facilities have been physically verified.

What are the best practices for negotiating with NCVD manufacturers?

Focus on Tiered Pricing based on volume; for orders exceeding 2,000 units, you should aim for a 15-20% discount compared to sample prices. Negotiate for OEM/Private Labeling (custom logo and color) to be included in the unit price at specific MOQs. Ensure the contract specifies a 12 to 24-month replacement warranty for any units that fail calibration.

What shipping precautions should be taken for electronic test equipment?

Since these devices often include batteries, they are classified as Dangerous Goods (UN3481) if lithium-based. To simplify logistics and reduce costs, consider sourcing units without batteries and installing them locally, or ensure the supplier provides a Material Safety Data Sheet (MSDS) and UN38.3 Test Report for air freight compliance.

How do I ensure transaction security in cross-border payments?

Utilize Secure Payment services provided by reputable platforms like Made-in-China.com to ensure funds are only released to the supplier after you confirm receipt of goods. Avoid direct wire transfers to unknown accounts; always verify the beneficiary name matches the company name on the business license.